CloudEdge Mobility D5 AWS Maintenance Smoke

Result: PASS

Date: 2026-05-31 Build: main 99eb1d45 Evidence bundle: /home/imksoo/routerd-labs/cloudedge-mobility/evidence/20260531T215831Z-d5-aws-rerun-99eb1d45

Scenario

  • AWS-only D5 live maintenance / capture migration.
  • Existing active router A was reused: i-001f62ac01d66e782, ENI-A eni-0d17f203a6717e4d9, primary 10.77.60.4.
  • Standby router B was recreated for this run: i-045382a4f5bbf6fc0, ENI-B eni-017dd140722f5d819, primary 10.77.60.14, t3.small.
  • AWS cloud client was reused: i-0c5d4e3578e7669a9, 10.77.60.11.
  • Captured address: on-prem client 10.77.60.10/32.

Initial Capture

  • A imported and executed:
    • assign-secondary-ip epoch 1 for 10.77.60.10/32 on ENI-A.
    • ensure-forwarding-enabled epoch 1 on ENI-A.
  • AWS provider state after initial execute:
    • ENI-A: 10.77.60.4,10.77.60.10, SourceDestCheck=false.
    • ENI-B: 10.77.60.14, SourceDestCheck=true.
  • Before migration dataplane:
    • cloud-client 10.77.60.11 -> 10.77.60.10 ping: 3/3, 0% loss.
    • SSH reached on-prem client with source preserved: SSH_CONNECTION=10.77.60.11 ... 10.77.60.10 22.

Drain And Migration

  • maintenance.drain=true was applied declaratively to router A.
  • A imported epoch 2 de-provision actions:
    • unassign-secondary-ip for 10.77.60.10/32 from ENI-A.
    • ensure-forwarding-disabled for ENI-A.
  • B imported epoch 2 active-capture actions:
    • assign-secondary-ip for 10.77.60.10/32 to ENI-B.
    • ensure-forwarding-enabled for ENI-B.
  • A unassign executed successfully and removed .10 from ENI-A.
  • B assign executed successfully and added .10 to ENI-B.
  • AWS provider state after migration:
    • ENI-A: 10.77.60.4, SourceDestCheck=true.
    • ENI-B: 10.77.60.14,10.77.60.10, SourceDestCheck=false.
  • Capture epoch converged to holder aws-router-b, epoch 2.

Epoch Fence

  • A epoch 1 actions succeeded before drain.
  • A epoch 2 unassign and forwarding-disable remained journaled until executed.
  • B epoch 2 assign and forwarding-enable executed successfully.
  • Stale gate was verified with a non-provider journal probe:
    • an epoch 1 pending action for the same capture key was inserted as d5-rerun-stale-probe-epoch1;
    • routerctl action import changed it to status=skipped;
    • result message: stale mobility capture epoch.

After Migration Dataplane

  • B side doctor hybrid: PASS.
  • B side routerd_mss: present for ens5 -> wg-hybrid.
  • On-prem routerd_mss: present for ens21 -> wg-hybrid.
  • After neighbor refresh, cloud-client 10.77.60.11 -> 10.77.60.10 ping passed 3/3 for three consecutive rounds.
  • SSH reached on-prem client through B with source preserved:
    • SSH_CONNECTION=10.77.60.11 ... 10.77.60.10 22.
  • Client default gateway remained unchanged: default via 10.77.60.1.

Teardown

  • Removed 10.77.60.10 from ENI-B.
  • Restored SourceDestCheck=true on ENI-A and ENI-B.
  • Restored IAM inline policy to the pre-B-scope document.
  • Terminated B.
  • Stopped A and cloud-client.
  • Final cost state:
    • A: stopped.
    • cloud-client: stopped.
    • B: terminated.
    • ENI-A baseline: only 10.77.60.4, SourceDestCheck=true.